Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 850
Filtrar
1.
Comput Methods Programs Biomed ; 251: 108204, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38728829

RESUMO

PURPOSE: This study aimed to investigate the effects of lower-extremity cannulation on the intra-arterial hemodynamic environment, oxygen content, blood damage, and thrombosis risk under different levels of veno-arterial (V-A) ECMO support. METHODS: Computational fluid dynamics methods were used to investigate the effects of different levels of ECMO support (ECMO flow ratios supplying oxygen-rich blood 100-40 %). Flow rates and oxygen content in each arterial branch were used to determine organ perfusion. A new thrombosis model considering platelet activation and deposition was proposed to determine the platelet activation and thrombosis risk at different levels of ECMO support. A red blood cell damage model was used to explore the risk of hemolysis. RESULTS: Our study found that partial recovery of cardiac function improved the intra-arterial hemodynamic environment, with reduced impingement of the intra-arterial flow field by high-velocity blood flow from the cannula, a flow rate per unit time into each arterial branch closer to physiological levels, and improved perfusion in the lower extremities. Partial recovery of cardiac function helps reduce intra-arterial high shear stress and residence time, thereby reducing blood damage. The overall level of hemolysis and platelet activation in the aorta decreased with the gradual recovery of cardiac contraction function. The areas at high risk of thrombosis under V-A ECMO femoral cannulation support were the aortic root and the area distal to the cannula, which moved to the descending aorta when cardiac function recovered to 40-60 %. However, with the recovery of cardiac contraction function, hypoxic blood pumped by the heart is insufficient in supplying oxygen to the front of the aortic arch, which may result in upper extremity hypoxia. CONCLUSION: We developed a thrombosis risk prediction model applicable to ECMO cannulation and validated the model accuracy using clinical data. Partial recovery of cardiac function contributed to an improvement in the aortic hemodynamic environment and a reduction in the risk of blood damage; however, there is a potential risk of insufficient perfusion of oxygen-rich blood to organs.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38695545

RESUMO

Advances in medical technology have enabled minimally invasive treatment of type A aortic dissection with accompanying aortic regurgitation. Implants include endovascular stent grafts (ESG) and heart valve substitute (HVS) modules. Traditional implants can be divided into two types based on the assembly relationship between ESG and HVS: separated z-shaped implants (SZ) and separated diamond-shaped implants (SD). This study proposes a novel linked diamond-shaped implant (LD). To evaluate the safety and effectiveness of this new implant, finite element simulation models were created to assess the risks of endoleak, migration, and vascular wall rupture under annulus displacement load. After the SZ, SD, and LD implants were grafted in virtual release method, all the implants can cover tear-entry located in the ascending aorta, but space distance (δ) which exposed to blood was 14.5, 13.1, and 7.4 mm, respectively; the maximum areas of contact gap was 76.5, 51.5 and 6.3 mm2; the maximum migration distance (ΔL1) were 1.27, 1.06, and 0.1 mm; the maximum stress on ascending aorta was 0.19, 0.24, and 0.51 MPa, which were lower than failure stress (0.9 MPa). This study showed that both SZ and SD implants had minimal effects on the ascending aorta; however, higher risks were associated with implant migration and proximal endoleak. In contrast, the LD implant can simplify the surgical procedure, has a lower risk of endoleak and migration, and limited stress stimulation of the aorta. This study validated the feasibility and effectiveness of this novel implant using the finite element method, indicating its potential as a secure and reliable treatment option.

3.
Sci Bull (Beijing) ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38664095

RESUMO

Brain aging is typically associated with a significant decline in cognitive performance. Vascular risk factors (VRF) and subsequent atherosclerosis (AS) play a major role in this process. Brain resilience reflects the brain's ability to withstand external perturbations, but the relationship of brain resilience with cognition during the aging process remains unclear. Here, we investigated how brain topological resilience (BTR) is associated with cognitive performance in the face of aging and vascular risk factors. We used data from two cross-ethnicity community cohorts, PolyvasculaR Evaluation for Cognitive Impairment and Vascular Events (PRECISE, n = 2220) and Sydney Memory and Ageing Study (MAS, n = 246). We conducted an attack simulation on brain structural networks based on k-shell decomposition and node degree centrality. BTR was defined based on changes in the size of the largest subgroup of the network during the simulation process. Subsequently, we explored the negative correlations of BTR with age, VRF, and AS, and its positive correlation with cognitive performance. Furthermore, using structural equation modeling (SEM), we constructed path models to analyze the directional dependencies among these variables, demonstrating that aging, AS, and VRF affect cognition by disrupting BTR. Our results also indicated the specificity of this metric, independent of brain volume. Overall, these findings underscore the supportive role of BTR on cognition during aging and highlight its potential application as an imaging marker for objective assessment of brain cognitive performance.

4.
Surg Innov ; 31(3): 307-317, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38606504

RESUMO

BACKGROUND: Reconstructing bone defects in the upper extremities and restoring their functions poses a significant challenge. In this study, we describe a novel workflow for designing and manufacturing customized bone cement molds using 3D printing technology to reconstruct upper extremity defects after bone tumor resection. METHODS: Computer tomography data was acquired from the unaffected upper extremities to create a detachable mold, which can be customized to fit the joint precisely by shaping the bone cement accordingly. Fourteen patients who underwent reconstructive surgery following bone tumor resection in the proximal humerus (13 cases) or distal radius (1 case) between January 2014 and December 2022 were retrospectively evaluated. The medical records of this case series were reviewed for the demographic, radiological, and operative data. Metastasis, local recurrence, and complication were also reviewed. Additionally, Musculoskeletal Tumor Society Score (MSTS) and Visual Analogue Scale (VAS) were used to assess clinical outcomes. RESULTS: The mean follow-up period was 49.36 ± 15.18 months (range, 27-82 months). At the end of follow-up, there were no cases of metastasis or recurrence, and patients did not experience complications such as infection, dislocation, or implant loosening. Two cases complicated with subluxation (14.3%), and 1 case underwent revision surgery for prosthetic fracture (7.1%). The average MSTS score was 23.2 ± 1.76 (77.4%, range, 66.7%-86.7%), and the postoperative VAS score was 1.86 ± 1.03 (range, 1-4), which was significantly lower than that before surgery (average preoperative VAS score was 5.21 ± 2.00 (range, 2-8)) (P < .001). CONCLUSION: Customized 3D molds can be utilized to shape bone cement prostheses, which may serve as a potential alternative for reconstructing the proximal humerus and distal radius following en bloc resection of bone tumors. This reconstruction strategy offers apparent advantages, including precise matching of articular surfaces and comparatively reduced costs.


Assuntos
Cimentos Ósseos , Neoplasias Ósseas , Procedimentos de Cirurgia Plástica , Impressão Tridimensional , Humanos , Cimentos Ósseos/uso terapêutico , Neoplasias Ósseas/cirurgia , Feminino , Masculino , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Adulto , Pessoa de Meia-Idade , Extremidade Superior/cirurgia , Rádio (Anatomia)/cirurgia , Adulto Jovem , Úmero/cirurgia , Adolescente , Idoso , Tomografia Computadorizada por Raios X
5.
J Biophotonics ; : e202400012, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659122

RESUMO

Focal damage due to stroke causes widespread abnormal changes in brain function and hemispheric asymmetry. In this study, functional near-infrared spectroscopy (fNIRS) was used to collect resting-state hemoglobin data from 85 patients with subacute stroke and 26 healthy controls, to comparatively analyze the characteristics of lateralization after stroke in terms of cortical activity, functional networks, and hemodynamic lags. Higher intensity of motor cortical activity, lower hemispheric autonomy, and more abnormal hemodynamic leads or lags were found in the affected hemisphere. Lateralization metrics of the three aspects were all associated with the Fugl-Meyer score. The results of this study prove that three lateralization metrics may provide clinical reference for stroke rehabilitation. Meanwhile, the present study piloted the use of resting-state fNIRS for analyzing hemodynamic lag, demonstrating the potential of fNIRS to assess hemodynamic abnormalities in addition to the study of cortical neurological function after stroke.

6.
Transl Vis Sci Technol ; 13(4): 11, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38578634

RESUMO

Background: The purpose of this study was to explore the protective effect of a shape memory polymeric shield on corneal endothelium during phacoemulsification in rabbits. Methods: Poly-(glycerol dodecanedioate) (PGD) with a transition temperature of 24.416°C was prepared to make a shape memory shield with a thickness of 100 µm, an arc length of 14 mm, and a radius of curvature of 8.8 mm. In the control group, a phaco-tip with bevel-down was used to simulate injury to the corneal endothelium by phacoemulsification in rabbits. In the experimental group, the pre-cooled and curled shape memory shield was injected into and removed from the anterior chamber before and after phaco-power release. Anterior segment optical coherence tomography (AS-OCT), confocal microscope, trypan blue/alizarin red staining, and scanning electron microscope were performed to measure endothelial damage after surgery. Results: One day postoperatively, the lost cell ratio of the control group and the experimental group were 28.08 ± 5.21% and 3.50 ± 1.43%, respectively (P < 0.0001), the damaged cell ratios were 11.83 ± 2.30% and 2.55 ± 0.52%, respectively (P < 0.0001), and the central corneal thicknesses (CCT) were 406.75 ± 16.74 µm and 340. 5 ±13.48 µm, respectively (P < 0.0001). Seven days postoperatively, the endothelial cell density (ECD) of the control group and the experimental group were 1674 ± 285/mm2 and 2561 ± 554/mm2, respectively (P < 0.05). The above differences were all statistically significant. Conclusions: This PGD based shape memory shield has a protective effect on corneal endothelium during phacoemulsification. It reduces postoperative corneal edema and ECD decrease in the short term after surgery. Translational Relevance: The shape memory PGD "shield" in this study may have a use in certain human patients with vulnerable corneas of low endothelial cell count or shallow anterior chambers.


Assuntos
Endotélio Corneano , Facoemulsificação , Animais , Humanos , Coelhos , Facoemulsificação/efeitos adversos , Facoemulsificação/métodos , Córnea , Câmara Anterior
7.
ASAIO J ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38569187

RESUMO

The rotor axial displacement of the full magnetic levitation blood pump varies with the operating conditions. The effect of rotor axial displacement on simulation results is unclear. This study aimed to evaluate the effect of rotor axial displacement on the predicted blood pump flow field, hydraulic performance, and hemocompatibility through simulation. This study used the CentriMag blood pump as a model, and conducted computational fluid dynamics simulations to assess the impact of rotor displacement. Considering rotor axial displacement leads to opposite results regarding predicted residence time and thrombotic risk compared with not considering rotor axial displacement. Not considering rotor axial displacement leads to deviations in the predicted values, where the effects on the flow field within the blood pump, ratio of secondary flow, and amount of shear stress >150 Pa are significant. The variation in the back clearance of the blood pump caused by the ideal and actual rotor displacements is the main cause of the above phenomena. Given that the rotor axial displacement significantly impacts the simulation accuracy, the effect of rotor axial displacement must be considered in the simulation.

8.
Ann Biomed Eng ; 52(6): 1706-1718, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38488988

RESUMO

Osteogenic differentiation of mesenchymal stem cells (MSCs) is proposed to be critical for bone tissue engineering and regenerative medicine. However, the current approach for evaluating osteogenic differentiation mainly involves immunohistochemical staining of specific markers which often can be detected at day 5-7 of osteogenic inducing. Deep learning (DL) is a significant technology for realizing artificial intelligence (AI). Computer vision, a branch of AI, has been proved to achieve high-precision image recognition using convolutional neural networks (CNNs). Our goal was to train CNNs to quantitatively measure the osteogenic differentiation of MSCs. To this end, bright-field images of MSCs during early osteogenic differentiation (day 0, 1, 3, 5, and 7) were captured using a simple optical phase contrast microscope to train CNNs. The results showed that the CNNs could be trained to recognize undifferentiated cells and differentiating cells with an accuracy of 0.961 on the independent test set. In addition, we found that CNNs successfully distinguished differentiated cells at a very early stage (only 1 day). Further analysis showed that overall morphological features of MSCs were the main basis for the CNN classification. In conclusion, MSCs differentiation detection can be achieved early and accurately through simple bright-field images and DL networks, which may also provide a potential and novel method for the field of cell detection in the near future.


Assuntos
Diferenciação Celular , Aprendizado Profundo , Células-Tronco Mesenquimais , Osteogênese , Células-Tronco Mesenquimais/citologia , Humanos , Células Cultivadas , Redes Neurais de Computação , Animais
9.
IEEE Trans Biomed Eng ; PP2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38536678

RESUMO

OBJECTIVE: Peripheral vascular disease is a worldwide leading health concern. Real-time peripheral hemoperfusion monitoring during treatment is essential to plan treatment strategies to improve circulatory enhancement effects. METHODS: The present work establishes a Janus flexible perfusion (JFP) sensor system for dynamic peripheral hemoperfusion monitoring. We develop a Janus structure design with different Young's modulus to improve the mechanical properties for motion artifacts suppression. Besides, we propose a peripheral perfusion index (PPI) to assess the peripheral hemoperfusion based on an optical perfusion model that is experimentally verified using an in-vitro model. The effectiveness of the system is assessed in three experimental scenarios, including motion artifact-robust test, induced vascular occlusion in upper limb, and peripheral hemoperfusion monitoring with the treatment of intermittent pneumatic compression (IPC), with comparison with Laser Doppler flowmetry (LDF). RESULTS: The noise level of the traditional rigid sensor is five times that of the JFP sensor within the effective signal frequency domain when there is movement. The PPI can effectively discriminate between different peripheral hemoperfusion states and has a correlation coefficient of 0.92 with the LDF mean values. The kappa statistic between the JFP sensor and LDF is 0.78, indicating substantial agreement between them to estimate the peripheral hemoperfusion improvements during IPC treatment. CONCLUSION: The sensor system we proposed can monitor peripheral hemoperfusion variation in real-time and is insensitive to motion artifacts. SIGNIFICANCE: The proposed sensing system provides a functional module for real-time estimation of peripheral hemoperfusion during clinical interventions.

10.
J Biomech ; 166: 112047, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38484653

RESUMO

To maintain the physiological dynamics of the mitral annulus, mitral annuloplasty rings (MAR) must be flexible. Enhanced flexibility implies decreased resistance to fatigue and potential for fatigue fracture. This study established new methods to test the flexible fatigue life of MAR in-vitro using numerical analysis; the purpose is that the fatigue test could reflect the real stress distribution in-vivo. Based on the conventional test methods (C1, D1), this paper presents a novel test method (C2, D2). Four testing methods for open-end annuloplasty rings (C1, C2) and closed-end annuloplasty rings (D1, D2) were modelled and their stress distribution calculated by finite element analysis. The mean absolute error (Χ) and the Pearson correlation coefficient (Φ) were used to quantify the difference in stress distribution between the loading modes in-vivo and in-vitro. For closed-end annuloplasty rings, the novel test method (D2) is not obvious better than conventional test methods(D1) in duplicating the stress distribution (ΦD1 = 0.88 vs ΦD2 = 0.92). However, the maximum values of stress in the novel test method are closer to the maximum value of stress under in-vivo loading (ΧD1 = 5.2Mpa vs ΧD2 = 4.4Mpa). For open-end annuloplasty rings, the novel test method(C2) is obviously superior to the conventional test method(C1) in duplicating both the stress distribution and the stress peak values of the in-vivo loading (ΦC1 = 0.22 vs ΦC2 = 0.98; ΧC1 = 59.1Mpa vs ΧC2 = 11.0Mpa). The in-vitro loading methods described in this article more closely approximated in-vivo conditions compared to traditional methods. They are simpler to operate, more efficient and can help manufacturers expedite new product development, assist regulatory agencies with product quality oversight.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Desenho de Prótese , Anuloplastia da Valva Mitral/métodos , Valva Mitral/cirurgia , Valva Mitral/fisiologia , Teste de Materiais , Insuficiência da Valva Mitral/cirurgia
11.
ACS Nano ; 18(12): 8777-8797, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38488479

RESUMO

Stem cell-derived extracellular vesicles (EVs) show great potential for promoting bone tissue regeneration. However, normal EVs (Nor-EVs) have a limited ability to direct tissue-specific regeneration. Therefore, it is necessary to optimize the osteogenic capacity of EV-based systems for repairing extensive bone defects. Herein, we show that hydrogels loaded with osteoinductive dental pulp stem cell-derived EVs (Ost-EVs) enhanced bone tissue remodeling, resulting in a 2.23 ± 0.25-fold increase in the expression of bone morphogenetic protein 2 (BMP2) compared to the hydrogel control group. Moreover, Ost-EVs led to a higher expression of alkaline phosphatase (ALP) (1.88 ± 0.16 of Ost-EVs relative to Nor-EVs) and the formation of orange-red calcium nodules (1.38 ± 0.10 of Ost-EVs relative to Nor-EVs) in vitro. RNA sequencing revealed that Ost-EVs showed significantly high miR-1246 expression. An ideal hydrogel implant should also adhere to surrounding moist tissues. In this study, we were drawn to mussel-inspired adhesive modification, where the hydrogel carrier was crafted from hyaluronic acid (HA) and polyethylene glycol derivatives, showcasing impressive tissue adhesion, self-healing capabilities, and the ability to promote bone growth. The modified HA (mHA) hydrogel was also responsive to environmental stimuli, making it an effective carrier for delivering EVs. In an ectopic osteogenesis animal model, the Ost-EV/hydrogel system effectively alleviated inflammation, accelerated revascularization, and promoted tissue mineralization. We further used a rat femoral condyle defect model to evaluate the in situ osteogenic ability of the Ost-EVs/hydrogel system. Collectively, our results suggest that Ost-EVs combined with biomaterial-based hydrogels hold promising potential for treating bone defects.


Assuntos
Vesículas Extracelulares , Hidrogéis , Ratos , Animais , Hidrogéis/farmacologia , Hidrogéis/metabolismo , Polpa Dentária , Diferenciação Celular , Regeneração Óssea , Osteogênese , Células-Tronco , Ácido Hialurônico/farmacologia , Vesículas Extracelulares/metabolismo
12.
Artigo em Inglês | MEDLINE | ID: mdl-38444287

RESUMO

Non-physiological blood flow conditions in axial blood pumps lead to some complications, including hemolysis, platelet activation, thrombosis, and embolism. The high speed of the axial blood pump destroys large amounts of erythrocytes, thereby causing hemolysis and thrombosis. Thus, this study aims to reduce the vortices and reflux in the flow field by optimizing the axial blood pump. The axial blood pump and arterial flow field were modeled by the finite element method. The blood was assumed to be incompressible, turbulent, and Newtonian. The SST k-ω turbulence model was used. The frozen rotor method was also used to calculate the snapshot of motion. Many vortices and reflux exist in the flow field of the blood pump without optimization. The improved flow field had almost no vortex and reflux, thereby reducing the exposure time of blood. The optimized blood pump had little influence on the pressure field and shear stress field. The optimized blood pump mainly reduced the vortex, reflux, and the risk of thrombosis in the flow field. The flow field characteristics of an axial blood pump were studied, and the results showed the risk of thrombosis and hemolysis in the blood pump. In accordance with the relationship between the blade shape and the flow field, the blade of the blood pump was optimized, reducing the vortex and reflux of the flow field, as well as the risk of thrombosis.

13.
Bioact Mater ; 35: 549-563, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38434800

RESUMO

The biophysical factors of biomaterials such as their stiffness regulate stem cell differentiation. Energy metabolism has been revealed an essential role in stem cell lineage commitment. However, whether and how extracellular matrix (ECM) stiffness regulates energy metabolism to determine stem cell differentiation is less known. Here, the study reveals that stiff ECM promotes glycolysis, oxidative phosphorylation, and enhances antioxidant defense system during osteogenic differentiation in MSCs. Stiff ECM increases mitochondrial fusion by enhancing mitofusin 1 and 2 expression and inhibiting the dynamin-related protein 1 activity, which contributes to osteogenesis. Yes-associated protein (YAP) impacts glycolysis, glutamine metabolism, mitochondrial dynamics, and mitochondrial biosynthesis to regulate stiffness-mediated osteogenic differentiation. Furthermore, glycolysis in turn regulates YAP activity through the cytoskeletal tension-mediated deformation of nuclei. Overall, our findings suggest that YAP is an important mechanotransducer to integrate ECM mechanical cues and energy metabolic signaling to affect the fate of MSCs. This offers valuable guidance to improve the scaffold design for bone tissue engineering constructs.

14.
FASEB J ; 38(6): e23538, 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38482729

RESUMO

Stem cells respond and remember mechanical cues from the microenvironment, which modulates their therapeutic effects. Chromatin organization and energy metabolism regulate the stem cell fate induced by mechanical cues. However, the mechanism of mechanical memory is still unclear. This study aimed to investigate the effects of mechanical amplitude, frequency, duration, and stretch cycle on mechanical memory in mesenchymal stem cells. It showed that the amplitude was the dominant parameter to the persistence of cell alignment. F-actin, paxillin, and nuclear deformation are more prone to be remolded than cell alignment. Stretching induces transcriptional memory, resulting in greater transcription upon subsequent reloading. Cell metabolism displays mechanical memory with sustained mitochondrial fusion and increased ATP production. The mechanical memory of chromatin condensation is mediated by histone H3 lysine 27 trimethylation, leading to much higher smooth muscle differentiation efficiency. Interestingly, mechanical memory can be transmitted based on direct cell-cell interaction, and stretched cells can remodel the metabolic homeostasis of static cells. Our results provide insight into the underlying mechanism of mechanical memory and its potential benefits for stem cell therapy.


Assuntos
Cromatina , Células-Tronco Mesenquimais , Cromatina/metabolismo , Estresse Mecânico , Diferenciação Celular , Células-Tronco Mesenquimais/metabolismo , Músculo Liso , Proliferação de Células
15.
ACS Sens ; 9(3): 1301-1309, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38373043

RESUMO

Continuous pulse wave detection can be used for monitoring and diagnosing cardiovascular diseases, and research on pulse sensing based on piezoelectric thin films is one of the hot spots. Usually, piezoelectric thin films do not come into direct contact with the skin and need to be connected through a layer of an elastic medium. Most views think that the main function of this layer of elastic medium is to increase the adhesion between the sensor component and the skin, but there is little discussion about the impact of the elastic medium on pulse vibration transmission. Here, we conducted a detailed study on the effects of Young's modulus and the thickness of elastic media on pulse sensing signals. The results show that the waveform amplitude of the piezoelectric sensing signal decreases with the increase of Young's modulus and thickness of the elastic medium. Then, we constructed a theoretical model of the influence of elastic media on pulse wave propagation. The amplitude of the pulse wave signal detected by the optimized sensor was increased to 480%. Our research shows that by regulating Young's modulus and thickness of elastic media, pulse wave signals can undergo a similar amplification effect, which has an important theoretical reference value for achieving ambulatory blood pressure monitoring based on high-quality pulse waves.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Elastômeros , Razão Sinal-Ruído , Módulo de Elasticidade , Modelos Teóricos
16.
ACS Nano ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38323542

RESUMO

Autoimmune diseases, allergies, transplant rejections, generation of antidrug antibodies, and chronic inflammatory diseases have impacted a large group of people across the globe. Conventional treatments and therapies often use systemic or broad immunosuppression with serious efficacy and safety issues. Tolerogenic vaccines represent a concept that has been extended from their traditional immune-modulating function to induction of antigen-specific tolerance through the generation of regulatory T cells. Without impairing immune homeostasis, tolerogenic vaccines dampen inflammation and induce tolerogenic regulation. However, achieving the desired potency of tolerogenic vaccines as preventive and therapeutic modalities calls for precise manipulation of the immune microenvironment and control over the tolerogenic responses against the autoantigens, allergens, and/or alloantigens. Engineered nano-/microparticles possess desirable design features that can bolster targeted immune regulation and enhance the induction of antigen-specific tolerance. Thus, particle-based tolerogenic vaccines hold great promise in clinical translation for future treatment of aforementioned immune disorders. In this review, we highlight the main strategies to employ particles as exciting tolerogenic vaccines, with a focus on the particles' role in facilitating the induction of antigen-specific tolerance. We describe the particle design features that facilitate their usage and discuss the challenges and opportunities for designing next-generation particle-based tolerogenic vaccines with robust efficacy to promote antigen-specific tolerance for immunotherapy.

17.
Adv Healthc Mater ; : e2303316, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38323711

RESUMO

Electrical neuromodulation plays a pivotal role in enhancing patient outcomes among individuals suffering from neurological disorders. Implantable neural interfaces are vital components of the electrical neuromodulation system to ensure desirable performance; However, conventional devices are limited to a single function and are constructed with bulky and rigid materials, which often leads to mechanical incompatibility with soft tissue and an inability to adapt to the dynamic and complex 3D structures of biological systems. In addition, current implantable neural interfaces utilized in clinical settings primarily rely on wire-based techniques, which are associated with complications such as increased risk of infection, limited positioning options, and movement restrictions. Here, the state-of-art applications of electrical neuromodulation are presented. Material schemes and device structures that can be employed to develop robust and multifunctional neural interfaces, including flexibility, stretchability, biodegradability, self-healing, self-rolling, or morphing are discussed. Furthermore, multimodal wireless neuromodulation techniques, including optoelectronics, mechano-electrics, magnetoelectrics, inductive coupling, and electrochemically based self-powered devices are reviewed. In the end, future perspectives are given.

18.
Int J Biol Macromol ; 264(Pt 1): 130357, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38395273

RESUMO

Natural polysaccharides and protein macromolecules are the important components of extracellular matrix (ECM), but individual component generally exhibits weak mechanical property, limited biological function or strong immunogenicity in tissue engineering. Herein, gelatin (Gel) was deposited to the stretched (65 %) chitosan (CS) hydrogel substrates to fabricate the polysaccharide-protein CS-Gel-65 % composite hydrogels to mimic the natural component of ECM and improve the above deficiencies. CS hydrogel substrates under different stretching deformations exhibited tunable morphology, chemical property and wettability, having a vital influence on the secondary structures of deposited fibrous Gel protein, namely appearing with the decreased ß-sheet content in stretched CS hydrogel. Gel also produced a more homogenous distribution on the stretched CS hydrogel substrate due to the unfolding of Gel and increased interactions between Gel and CS than on the unstretched substrate. Moreover, the polysaccharide-protein composite hydrogel possessed enhanced mechanical property and oriented structure via stretching-drying method. Besides, in vivo subcutaneous implantation indicated that the CS-Gel-65 % composite hydrogel showed lower immunogenicity, thinner fibrous capsule, better angiogenesis effect and increased M2/M1 of macrophage phenotype. Polysaccharide-protein CS-Gel-65 % composite hydrogel offers a novel material as a tissue engineering scaffold, which could promote angiogenesis and build a good immune microenvironment for the damaged tissue repair.


Assuntos
Quitosana , Quitosana/química , Hidrogéis/química , Gelatina/química , Alicerces Teciduais/química , Engenharia Tecidual
19.
Med Biol Eng Comput ; 62(6): 1821-1836, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38401007

RESUMO

In clinical research, the segmentation of irregularly shaped nuclei, particularly in mesenchymal areas like fibroblasts, is crucial yet often neglected. These irregular nuclei are significant for assessing tissue repair in immunotherapy, a process involving neovascularization and fibroblast proliferation. Proper segmentation of these nuclei is vital for evaluating immunotherapy's efficacy, as it provides insights into pathological features. However, the challenge lies in the pronounced curvature variations of these non-convex nuclei, making their segmentation more difficult than that of regular nuclei. In this work, we introduce an undefined task to segment nuclei with both regular and irregular morphology, namely multi-shape nuclei segmentation. We propose a proposal-based method to perform multi-shape nuclei segmentation. By leveraging the two-stage structure of the proposal-based method, a powerful refinement module with high computational costs can be selectively deployed only in local regions, improving segmentation accuracy without compromising computational efficiency. We introduce a novel self-attention module to refine features in proposals for the sake of effectiveness and efficiency in the second stage. The self-attention module improves segmentation performance by capturing long-range dependencies to assist in distinguishing the foreground from the background. In this process, similar features get high attention weights while dissimilar ones get low attention weights. In the first stage, we introduce a residual attention module and a semantic-aware module to accurately predict candidate proposals. The two modules capture more interpretable features and introduce additional supervision through semantic-aware loss. In addition, we construct a dataset with a proportion of non-convex nuclei compared with existing nuclei datasets, namely the multi-shape nuclei (MsN) dataset. Our MSNSegNet method demonstrates notable improvements across various metrics compared to the second-highest-scoring methods. For all nuclei, the D i c e score improved by approximately 1.66 % , A J I by about 2.15 % , and D i c e obj by roughly 0.65 % . For non-convex nuclei, which are crucial in clinical applications, our method's A J I improved significantly by approximately 3.86 % and D i c e obj by around 2.54 % . These enhancements underscore the effectiveness of our approach on multi-shape nuclei segmentation, particularly in challenging scenarios involving irregularly shaped nuclei.


Assuntos
Núcleo Celular , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
20.
Biomed Eng Online ; 23(1): 22, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38369455

RESUMO

BACKGROUND: Adolescent idiopathic scoliosis (AIS), three-dimensional spine deformation, affects body motion. Previous research had indicated pathological gait patterns of AIS. However, the impact of the curve number on the walking mechanism has not been established. Therefore, this study aimed to compare the gait symmetry and kinematics in AIS patients with different curve numbers to healthy control. RESULTS: In the spinal region, double curves AIS patients demonstrated a smaller sagittal symmetry angle (SA) and larger sagittal convex ROM of the trunk and lower spine than the control group. In the lower extremities, the single curve patients showed a significantly reduced SA of the knee joint in the frontal plane, while the double curves patients showed a significantly reduced SA of the hip in the transverse plane. CONCLUSION: The curve number indeed affects gait symmetry and kinematics in AIS patients. The double curves patients seemed to adopt a more "careful walking" strategy to compensate for the effect of spinal deformation on sensory integration deficits. This compensation mainly occurred in the sagittal plane. Compared to double curves patients, single curve patients unitized a similar walking strategy with healthy subjects.


Assuntos
Escoliose , Humanos , Adolescente , Fenômenos Biomecânicos , Caminhada , Coluna Vertebral , Marcha
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA